In certain circumstances, to restore the server to the initial factory default state may be necessary, normally through webpage (Miscellaneous Operation). If the user can't get into webpage (e.g. Missing of Username and Password information), then he can use the Emergency Factory Default to restore the factory default.
Procedures are as below:
Turn the power off
Connect GPIO Input 4 to GND:
Short GPIO Mini-Din Pin 5 & Pin 9 with small wire or switch.
Turn the power on. When the Status LED starts to blink (orange) twice, and then open the wire or switch that set GPIO Input 4 back to open immediately.
Server will restore the factory default and restart.
Note : When status LED starts to blink during power up, if not to set GPIO Input 4 back to open within 3 seconds , server will continue the boot sequence and doesn't retrieve the factory default.